Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 79
Filtrar
1.
Cardiovasc Ultrasound ; 22(1): 5, 2024 May 14.
Artículo en Inglés | MEDLINE | ID: mdl-38745211

RESUMEN

BACKGROUND: Coronary microvascular dysfunction (CMD) refers to structural and functional abnormalities of the coronary microcirculation, which may be diagnosed using invasive coronary physiology. CMD is responsible for impaired diastolic cardiac function. It has recently been suggested that left atrial strain (LASr) represents a highly sensitive tool for detecting cardiac diastolic function abnormalities. Accordingly, the aim of this study was to investigate the relationship between CMD and LASr. METHODS: Consecutively enrolled patients with non-obstructed coronary arteries (NOCA) underwent CMD and LASr evaluation by invasive thermodilution and noninvasive echocardiography, respectively. RESULTS: Forty-two (42) patients were included, out of which 26 presented with CMD. There were no significant differences between CMD-positive and negative patients in terms of clinical and echocardiographic characteristics. LASr was significantly reduced in patients with CMD (24.6% ± 6.1 vs. 30.3 ± 7.8%, p = 0.01). A moderate correlation was observed between coronary flow reserve and LAsr (r = 0.47, p = 0.002). A multivariate logistic regression analysis demonstrated that CMD was independently associated with LASr (OR = 0.88, 95%CI 0.78-0.99.135, p = 0.04). A LASr cut-off of 25.5% enabled an optimal classification of patients with or without CMD. CONCLUSION: Patients with NOCA and CMD had a significantly reduced LASr compared with patients without CMD, suggesting the early impairment of diastolic function in these patients.


Asunto(s)
Circulación Coronaria , Vasos Coronarios , Ecocardiografía , Atrios Cardíacos , Microcirculación , Humanos , Masculino , Femenino , Microcirculación/fisiología , Persona de Mediana Edad , Circulación Coronaria/fisiología , Atrios Cardíacos/fisiopatología , Atrios Cardíacos/diagnóstico por imagen , Ecocardiografía/métodos , Vasos Coronarios/fisiopatología , Vasos Coronarios/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/fisiopatología , Enfermedad de la Arteria Coronaria/diagnóstico , Enfermedad de la Arteria Coronaria/complicaciones , Anciano , Función del Atrio Izquierdo/fisiología , Termodilución/métodos , Diástole
3.
Microcirculation ; 31(2): e12843, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38174616

RESUMEN

INTRODUCTION: Coronary microvascular dysfunction (CMD) plays a major role in hypertrophic cardiomyopathy (HCM) physiopathology but its assessment in clinical practice remains a challenge. Nowadays, innovations in invasive and noninvasive coronary evaluation using multimodal imaging provide options for the diagnosis of CMD. The objective of the present study was to investigate if new multimodal imaging diagnosis of CMD could detect HCM patients with more impaired cardiac function by left atrioventricular coupling index (LACI). METHODS AND RESULTS: A total of 32 consecutive patients with a confirmed diagnosis of HCM (62 ± 13 years, 62% men) were prospectively screened for CMD using a multimodal imaging method. LACI was assessed by cardiovascular magnetic resonance imaging. Fifteen (47%) patients had CMD by multimodal imaging method. Patients with CMD presented a significantly higher LACI (48.5 ± 25.4 vs. 32.5 ± 10.6, p = .03). A multivariate logistic regression analysis demonstrated that CMD was independently associated with LACI (OR = 1.069, 95% CI 1.00-1.135, p = .03). CONCLUSION: Multimodal imaging diagnosis of CMD is applicable to HCM patients and is associated with more impaired cardiac function.


Asunto(s)
Cardiomiopatía Hipertrófica , Isquemia Miocárdica , Masculino , Humanos , Femenino , Circulación Coronaria , Cardiomiopatía Hipertrófica/diagnóstico por imagen , Imagen por Resonancia Magnética , Imagen Multimodal
5.
Comput Methods Programs Biomed ; 242: 107841, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37865006

RESUMEN

BACKGROUND AND OBJECTIVE: Automatic segmentation of myocardial infarction is of great clinical interest for the quantitative evaluation of myocardial infarction (MI). Late Gadolinium Enhancement cardiac MRI (LGE-MRI) is commonly used in clinical practice to quantify MI, which is crucial for clinical diagnosis and treatment of cardiac diseases. However, the segmentation of infarcted tissue in LGE-MRI is highly challenging due to its high anisotropy and inhomogeneities. METHODS: The innovative aspect of our work lies in the utilization of a probability map of the healthy myocardium to guide the localization of infarction, as well as the combination of 2D U-Net and U-Net transformers to achieve the final segmentation. Instead of employing a binary segmentation map, we propose using a probability map of the normal myocardium, obtained through a dedicated 2D U-Net. To leverage spatial information, we employ a U-Net transformers network where we incorporate the probability map into the original image as an additional input. Then, To address the limitations of U-Net in segmenting accurately the contours, we introduce an adapted loss function. RESULTS: Our method has been evaluated on the 2020 MICCAI EMIDEC challenge dataset, yielding competitive results. Specifically, we achieved a Dice score of 92.94% for the myocardium and 92.36% for the infarction. These outcomes highlight the competitiveness of our approach. CONCLUSION: In the case of the infarction class, our proposed method outperforms state-of-the-art techniques across all metrics evaluated in the challenge, establishing its superior performance in infarction segmentation. This study further reinforces the importance of integrating a contour loss into the segmentation process.


Asunto(s)
Procesamiento de Imagen Asistido por Computador , Infarto del Miocardio , Humanos , Procesamiento de Imagen Asistido por Computador/métodos , Medios de Contraste , Gadolinio , Imagen por Resonancia Magnética/métodos , Infarto del Miocardio/diagnóstico por imagen , Redes Neurales de la Computación
6.
Am J Cardiol ; 205: 207-213, 2023 10 15.
Artículo en Inglés | MEDLINE | ID: mdl-37611412

RESUMEN

The management of anxiety because of upcoming invasive coronary angiography (ICA) remains suboptimal. Previously published studies investigating the potential of virtual reality (VR) for the reduction of anxiety in ICA procedures used a subjective evaluation method. The purpose of this study was to determine whether the use of a VR program before ICA objectively decreases anxiety as assessed by the SD of normal to normal (SDNN). Lower SDNN is associated with worse anxiety. A total of 156 patients referred for ICA after a positive noninvasive test for coronary disease were included in the present randomized study. The interventional group benefited from the use of a VR mask in the transfer room before ICA, whereas the control group underwent the procedure as usual. In both groups, SDNN was measured before ICA. No statistical difference in SDNN was observed between the VR and control groups (45.5 ± 17.8 vs 50.6 ± 19.5, p = 0.12). The preoperative use of a VR mask for anxiolytic purposes in the setting of ICA did not result in a decrease in anxiety.


Asunto(s)
Cardiología , Enfermedad de la Arteria Coronaria , Realidad Virtual , Humanos , Ansiedad , Trastornos de Ansiedad
7.
Diagnostics (Basel) ; 13(11)2023 Jun 05.
Artículo en Inglés | MEDLINE | ID: mdl-37296830

RESUMEN

Advances in computer technology and image processing now allow us to obtain from angiographic images a large variety of information on coronary physiology without the use of a guide-wire as a diagnostic information equivalent to FFR and iFR but also information allowing for the performance of a real virtual percutaneous coronary intervention (PCI) and finally the ability to obtain information to optimize the results of PCI. With specific software, it is now possible to have a real upgrading of invasive coronary angiography. In this review, we present the different advances in this field and discuss the future perspectives offered by this technology.

8.
J Nucl Cardiol ; 30(4): 1656-1667, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-36813934

RESUMEN

OBJECTIVES: To assess the diagnostic performances of CZT myocardial perfusion reserve (MPR) for the detection of territories with simultaneous impaired coronary flow reserve (CFR) and index of microcirculatory resistance (IMR) in patients without obstructive coronary artery disease. METHODS: Patients were prospectively included before being referred for coronary angiography. All patients underwent CZT MPR before invasive coronary angiography (ICA) and coronary physiology assessment. Rest and dipyridamole-induced stress myocardial blood flow (MBF) and MPR were quantified using 99mTc-SestaMIBI and a CZT camera. Fractional flow reserve (FFR), Thermodilution CFR, and IMR were assessed during ICA. RESULTS: Between December 2016 and July 2019, 36 patients were included. 25/36 patients presented no obstructive coronary artery disease. A complete functional assessment was performed in 32 arteries. No territory presented a significant ischemia on CZT myocardial perfusion imaging. A moderate yet significant correlation was observed between regional CZT MPR and CFR (r = 0.4, P = .03). Sensitivity, specificity, positive and negative predictive value, and accuracy of regional CZT MPR versus the composite invasive criterion (impaired CFR and IMR) were 87 [47% to 99%], 92% [73% to 99%], 78% [47% to 93%], 96% [78% to 99%], and 91% [75% to 98%], respectively. All territories with a regional CZT MPR ≤ 1.8 showed a CFR < 2. Regional CZT MPR values were significantly higher in arteries with CFR ≥ 2 and IMR < 25 (negative composite criterion, n = 14) than in those with CFR < 2 and IMR ≥ 25 (2.6 [2.1 to 3.6] versus 1.6 [1.2 to 1.8]), P < .01). CONCLUSION: Regional CZT MPR presented excellent diagnostic performances for the detection of territories with simultaneously impaired CFR and IMR reflecting a very high cardiovascular risk in patients without obstructive coronary artery disease.


Asunto(s)
Enfermedad de la Arteria Coronaria , Reserva del Flujo Fraccional Miocárdico , Imagen de Perfusión Miocárdica , Humanos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Proyectos Piloto , Reserva del Flujo Fraccional Miocárdico/fisiología , Microcirculación/fisiología , Angiografía Coronaria , Perfusión , Imagen de Perfusión Miocárdica/métodos
9.
Eur Respir J ; 61(2)2023 02.
Artículo en Inglés | MEDLINE | ID: mdl-36229051

RESUMEN

BACKGROUND: Adaptive servo-ventilation (ASV) effectively suppresses central sleep apnoea (CSA) but has been associated with increased all-cause and cardiovascular mortality in chronic heart failure patients with reduced ventricular ejection fraction (HFrEF). All-cause and, especially, cardiovascular mortality in chronic heart failure is highly correlated with sympathetic tone. This analysis of SERVE-HF data investigated the effect of ASV on sympathetic tone in patients with HFrEF and CSA. METHODS: HFrEF patients in the SERVE-HF trial (left ventricular ejection fraction (LVEF) ≤45%, apnoea-hypopnoea index (AHI) ≥15 events·h-1 with predominant CSA) were randomly assigned to receive guideline-based heart failure treatment alone (controls) or plus ASV. For this analysis, the primary outcome was change in muscle sympathetic nerve activity (MSNA) at 3-month follow-up. The effects of baseline MSNA and change in MSNA over time on mortality in the main study were also assessed. RESULTS: 40 patients with HFrEF were included in this analysis (age 71.3±11.7 years, LVEF 34.2±7.7%, 57.5% in New York Heart Association (NYHA) Functional Class II, 42.5% in NYHA Functional Class III, AHI 35.2±11 events·h-1). Sympathetic tone evolution during follow-up did not differ between groups (controls: 47.6±8.3 bursts·min-1 at baseline to 44.6±11.2 bursts·min-1; ASV group: 43.0±9.0 bursts·min-1 at baseline to 42.74±9.45 bursts·min-1). The reduction in sympathetic tone was associated with significantly increased cardiovascular mortality in the ASV group, whereas in the control group reduced sympathetic tone appeared to be protective. CONCLUSIONS: Suppression of CSA with ASV did not seem to have a significant effect on chronic heart failure-related sympathetic activation. Simultaneous suppression of CSA and reduction in MSNA was associated with increased cardiovascular mortality.


Asunto(s)
Insuficiencia Cardíaca Sistólica , Insuficiencia Cardíaca , Apnea Central del Sueño , Anciano , Anciano de 80 o más Años , Humanos , Persona de Mediana Edad , Insuficiencia Cardíaca/complicaciones , Insuficiencia Cardíaca/terapia , Insuficiencia Cardíaca Sistólica/complicaciones , Insuficiencia Cardíaca Sistólica/terapia , Músculos , Respiración , Apnea Central del Sueño/complicaciones , Apnea Central del Sueño/terapia , Volumen Sistólico/fisiología , Resultado del Tratamiento , Función Ventricular Izquierda/fisiología
12.
PLoS One ; 17(5): e0268330, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35576227

RESUMEN

Coronary microvascular dysfunction (CMVD) is common and associated with poorer outcomes in patients with ST Segment Elevation Myocardial Infarction (STEMI). The index of microcirculatory resistance (IMR) and the index of hyperemic microvascular resistance (HMR) are both invasive indexes of microvascular resistance proposed for the diagnosis of severe CMVD after primary percutaneous coronary intervention (pPCI). However, these indexes are not routinely assessed in STEMI patients. Our main objective was to clarify the association between IMR or HMR and long-term major adverse cardiovascular events (MACE), through a systematic review and meta-analysis of observational studies. We searched Medline, PubMed, and Google Scholar for studies published in English until December 2020. The primary outcome was a composite of cardiovascular death, non-cardiovascular death, non-fatal myocardial infarction, non-fatal stroke, and rehospitalization for heart failure occurring after at least 6 months following CMVD assessment. We identified 6 studies, reporting outcomes in 1094 patients (mean age 59.7 ± 11.4 years; 18.2% of patients were women) followed-up from 6 months to 7 years. Severe CMVD, defined as IMR > 40 mmHg or HMR > 3mmHg/cm/sec was associated with MACE with a pooled HR of 3.42 [2.45; 4.79]. Severe CMVD is associated with an increased risk of long-term adverse cardiovascular events in patients with STEMI. Our results suggest that IMR and HMR are useful for the early identification of severe CMVD in patients with STEMI after PCI, and represent powerful prognostic assessments as well as new therapeutic targets for clinical intervention.


Asunto(s)
Intervención Coronaria Percutánea , Infarto del Miocardio con Elevación del ST , Anciano , Circulación Coronaria , Femenino , Humanos , Masculino , Microcirculación , Persona de Mediana Edad , Estudios Observacionales como Asunto , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/métodos , Valor Predictivo de las Pruebas , Pronóstico , Infarto del Miocardio con Elevación del ST/diagnóstico , Resultado del Tratamiento , Resistencia Vascular
13.
Front Cardiovasc Med ; 9: 836473, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35282382

RESUMEN

Atherosclerotic plaque rupture or erosion remain the primary mechanism responsible for myocardial infarction and the major challenge of cardiovascular researchers is to develop non-invasive methods of accurate risk prediction to identify vulnerable plaques before the event occurs. Multimodal imaging, by CT-TEP or CT-SPECT, provides both morphological and activity information about the plaque and cumulates the advantages of anatomic and molecular imaging to identify vulnerability features among coronary plaques. However, the rate of acute coronary syndromes remains low and the mechanisms leading to adverse events are clearly more complex than initially assumed. Indeed, recent studies suggest that the detection of a state of vulnerability in a patient is more important than the detection of individual sites of vulnerability as a target of focal treatment. Despite this evolution of concepts, multimodal imaging offers a strong potential to assess patient's vulnerability. Here we review the current state of multimodal imaging to identify vulnerable patients, and then focus on emerging imaging techniques and precision medicine.

14.
Joint Bone Spine ; 89(4): 105375, 2022 07.
Artículo en Inglés | MEDLINE | ID: mdl-35259478

RESUMEN

OBJECTIVES: Axial Spondyloarthritis (ax-SpA) is associated with increased risk of cardiovascular disease (CVD)-specific deaths. We aimed to assess the prevalence of left ventricular (LV) systolic and diastolic dysfunction and valvular heart disease (VHD) by transthoracic echocardiography (TTE) in ax-SpA patients without history of CVD. METHODS: A systematic literature review was performed in PUBMED, Embase, Cochrane Library databases published before April 2020. We included all controlled studies assessing myocardial function and heart valve by TTE in ax-SpA without history of CVD. A meta-analysis was performed with random or fixed effects model estimating mean differences (MD) and odds ratio (OR). RESULTS: Literature search selected 189 abstracts and 28 articles were included (1471 ax-SpA and 1115 controls). ax-SpA had a statistically slight alteration of LV ejection fraction (MD=0.64%, 95%CI: 0.14-1.14). ax-SpA had more frequently LV diastolic dysfunction (OR=3.43, 95%CI: 1.78-6.59) and an alteration of E/A ratio (MD=0.15, 95%CI: 0.08-0.21), deceleration time (MD=13.07ms, 95%CI: 7.75-18.40), isovolumetric relaxation time (MD=7.90ms, 95%CI: 4.50-11.30), left-ventricular end diastolic (MD=0.57mm, 95%CI: 0.19-0.95) and systolic (MD=0.77mm, 95%CI: 0.36-1.17) diameters. Three studies (15%) used a combination of TTE parameters to diagnose LV diastolic dysfunction. Prevalence of mitral regurgitation and aortic regurgitation were similar in ax-SpA patients and healthy individuals. CONCLUSION: ax-SpA have a non-clinically relevant alteration of LV ejection fraction and similar prevalence of VHD compared to healthy individuals. LV diastolic TTE parameters are altered in ax-SpA. However, most studies do not combine set of parameters to recognize diastolic dysfunction. The clinical relevance of diastolic dysfunction observed by TTE remains to be determined in future longitudinal studies.


Asunto(s)
Espondiloartritis Axial , Disfunción Ventricular Izquierda , Ecocardiografía , Válvulas Cardíacas , Humanos , Disfunción Ventricular Izquierda/complicaciones , Disfunción Ventricular Izquierda/diagnóstico por imagen , Disfunción Ventricular Izquierda/epidemiología , Función Ventricular Izquierda
15.
Eur J Nucl Med Mol Imaging ; 49(3): 809-820, 2022 02.
Artículo en Inglés | MEDLINE | ID: mdl-34417856

RESUMEN

PURPOSE: Coronary microvascular dysfunction (CMVD) plays a major role in the occurrence of cardiovascular events (CVE). We recently suggested the clinical potential of myocardial perfusion entropy (MPE) quantification from SPECT myocardial perfusion images (MPI) for the prognosis of CVE occurrence. We hypothesized that the quantification of MPE from SPECT MPI would allow the assessment of CMVD-related MPE variations in a preclinical model of type 2 diabetes (T2D) including treatment with the anti-diabetic incretin liraglutide (LIR). METHODS: Optimal conditions for the preclinical quantification of MPE using 201Tl SPECT MPI were determined in rats with a T2D-like condition induced by a high-fat diet and streptozotocin injection (feasibility study, n = 43). Using such conditions, echocardiography and post-mortem LV capillary density evaluation were then used in order to assess the effect of LIR and the ability of MPE to assess CMVD (therapeutic study, n = 39). RESULTS: The feasibility study identified dobutamine stress and acute NO synthase and cyclooxygenase inhibition as optimal conditions for the quantification of MPE, with significant increases in MPE being observed in T2D animals (P < 0.01 vs controls). In the therapeutic study, T2D rats were hyperglycemic (5.5 ± 0.5 vs 1.1 ± 0.3 g/L for controls, P < 0.001) and had a significantly lower left ventricular ejection fraction (LVEF) (65 ± 4% vs 74 ± 9%, P < 0.01) and LV capillary density (2400 ± 300 vs 2800 ± 600 mm-3, P < 0.05). LIR partially restored glycemia (3.9 ± 0.6 g/L, P < 0.05 vs controls and T2D), totally prevented LVEF impairment (72 ± 7%, P = NS vs CTL), with no significant effect on capillary density. MPE was significantly increased in T2D rats (7.6 ± 0.5 vs 7.1 ± 0.5, P < 0.05), with no significant improvement in T2D-LIR rats (7.4 ± 0.4, P = NS vs controls and T2D). CONCLUSION: MPE quantification allowed the preclinical noninvasive assessment of CMVD. Both MPE and capillary density quantification suggested that LIR did not improve T2D-induced CMVD. The relevance of MPE for CMVD assessment warrants further clinical investigation.


Asunto(s)
Diabetes Mellitus Tipo 2 , Imagen de Perfusión Miocárdica , Animales , Diabetes Mellitus Tipo 2/complicaciones , Diabetes Mellitus Tipo 2/diagnóstico por imagen , Entropía , Imagen de Perfusión Miocárdica/métodos , Perfusión , Ratas , Roedores , Volumen Sistólico , Tomografía Computarizada de Emisión de Fotón Único/métodos , Función Ventricular Izquierda/fisiología
16.
J Nucl Cardiol ; 29(4): 1647-1656, 2022 08.
Artículo en Inglés | MEDLINE | ID: mdl-33988809

RESUMEN

AIMS: The objective of this study was to determine the accuracy of right ventricular function (RVF) assessed by Cadmium Zinc Telluride ECG-gated SPECT equilibrium radionuclide angiocardiography (CZT-ERNA). METHODS AND RESULTS: Twenty-one consecutive patients with cardiomyopathy (aged 54 ± 19 years; 62% male) were included. RV ejection fraction (EF) and volumes were analyzed by CZT-ERNA and compared with values obtained by cardiac magnetic resonance imaging (CMR). Mean values were not different between CZT-ERNA and MRI for RVEF (48.1 ± 10.4% vs 50.8 ± 10.0%; P = .23). Significant correlations (P < .0001) were observed between CZT-ERNA and MRI for RVEF, RV end-diastolic volume, and end-systolic volume (r = 0.81, r = 0.93, and r = 0.96, respectively). Bland-Altman analysis showed a mean difference (bias) between CZT-ERNA and MRI for RVEF of -2.69% (95% CI - 5.35 to - 0.42) with good agreement between the 2 techniques (limits of agreement, -14.3 to 8.99). Intraobserver and interobserver reproducibility of RVF measured by CZT-ERNA was high. CONCLUSION: CZT-ERNA provides accurate, reproducible assessment of RVF and appears as a good alternative to cardiac magnetic resonance for the evaluation of the magnitude of RVF in patients with cardiomyopathy.


Asunto(s)
Cardiomiopatías , Imagen de Acumulación Sanguínea de Compuerta , Cadmio , Cardiomiopatías/diagnóstico por imagen , Electrocardiografía , Femenino , Imagen de Acumulación Sanguínea de Compuerta/métodos , Humanos , Imagen por Resonancia Magnética/métodos , Masculino , Reproducibilidad de los Resultados , Volumen Sistólico , Tomografía Computarizada de Emisión de Fotón Único/métodos , Zinc
17.
Catheter Cardiovasc Interv ; 99(2): 397-404, 2022 02.
Artículo en Inglés | MEDLINE | ID: mdl-34057279

RESUMEN

BACKGROUND: Highly thrombotic coronary lesions continue to be a serious and clinically significant problem that is not effectively and completely addressed by current technology. OBJECTIVES: We aimed to investigate whether a micro-net mesh (MNM) technology covering stent could preserve the index of microcirculatory resistance (IMR) after percutaneous coronary intervention (PCI) in patients with high thrombus burden. METHODS AND RESULTS: Fifty-two patients with non-ST elevation myocardial infarction or ST Elevation Myocardial Infarction and high thrombus burden (TIMI thrombus grade ≥ 3) were randomized into two groups, PCI with a MNM covering stent (MNM group, n = 25) and PCI with any commercially available stent (DES group, n = 27). As the primary endpoint, IMR was measured immediately after PCI using a pressure-temperature sensor-tipped coronary wire. The secondary endpoint was left ventricular ejection fraction (LVEF) at 6 months of follow-up. The IMR in the MNM group was significantly lower in comparison to the DES group (33.2 [21.3, 48.9] vs. 57.2 [39.9, 98.0], p = 0.005). No significant differences were observed in baseline LVEF (54.5 ± 10.2% vs. 53.1 ± 6.87%, p = .57), while LVEF was significantly improved at follow-up in the MNM group (61.1 ± 7.1% vs. 53.9 ± 6.35%, p = .0001). CONCLUSION: MNM technology significantly improved coronary microvascular dysfunction after PCI in patient with acute coronary syndrome and appears as a useful technological option for thrombus management.


Asunto(s)
Intervención Coronaria Percutánea , Trombosis , Humanos , Microcirculación , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/métodos , Stents , Volumen Sistólico , Mallas Quirúrgicas , Tecnología , Resultado del Tratamiento , Función Ventricular Izquierda
18.
J Nucl Cardiol ; 29(3): 1419-1429, 2022 06.
Artículo en Inglés | MEDLINE | ID: mdl-33502690

RESUMEN

BACKGROUND: Myocardial insulin resistance (IR) could be a predictive factor of cardiovascular events. This study aimed to introduce a new method using 123I-6-deoxy-6-iodo-D-glucose (6DIG), a pure tracer of glucose transport, for the assessment of IR using cardiac dynamic nuclear imaging. METHODS: The protocol evaluated first in rat-models consisted in two 6DIG injections and one of insulin associated with planar imaging and blood sampling. Compartmental modeling was used to analyze 6DIG kinetics in basal and insulin conditions and to obtain an index of IR. As a part of a translational approach, a clinical study was then performed in 5 healthy and 6 diabetic volunteers. RESULTS: In rodent models, the method revealed reproducible when performed twice at 7 days apart in the same animal. Rosiglitazone, an insulin-sensitizing drug, induced a significant increase of myocardial IR index in obese Zucker rats from 0.96 ± 0.18 to 2.26 ± 0.44 (P<.05) after 7 days of an oral treatment, and 6DIG IR indexes correlated with the gold standard IR index obtained through the hyperinsulinemic-euglycemic clamp (r=.68, P<.02). In human, a factorial analysis was applied on images to obtain vascular and myocardial kinetics before compartmental modeling. 1.5-fold to 2.2-fold decreases in mean cardiac IR indexes from healthy to diabetic volunteers were observed without reaching statistical significance. CONCLUSIONS: These preclinical results demonstrate the reproducibility and sensibility of this novel imaging methodology. Although this first in-human study showed that this new method could be rapidly performed, larger studies need to be planned in order to confirm its performance.


Asunto(s)
Diabetes Mellitus Tipo 2 , Diabetes Mellitus , Resistencia a la Insulina , Animales , Glucemia , Técnica de Clampeo de la Glucosa , Humanos , Insulina , Ratas , Ratas Zucker , Reproducibilidad de los Resultados
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...